Shopping cart

Why Cooling Your Water Tank Is Critical for UAE Poultry Farms

DURUB WATER SOLUTIONS – Cooling & Circulation Engineering Division

1. Introduction

In UAE poultry farms, water temperature is a silent factor that affects productivity more than most owners realize.
When tank water reaches 35–45°C in summer (which is normal here), birds immediately suffer from:

  • reduced water intake
  • stress and dehydration
  • weaker immunity
  • slow growth
  • higher mortality
  • lower feed conversion rate (FCR)
  • poor egg production


Cooling the tank is not a luxury — it is essential for maintaining bird health and farm profitability.
This report explains the engineering requirements for designing an effective tank cooling system for UAE farms.


2. How Hot Water Impacts Bird Health

1. Reduced Drinking Water Intake

Birds naturally avoid hot water; even a 3–5°C increase makes them consume less.

Water intake ↓ → Feed intake ↓ → Weight gain ↓

2. Increased Heat Stress

Hot water does not cool the bird’s internal temperature, causing constant heat stress.

3. Lower Growth Rate

Broilers grow slower when water exceeds 30°C.

4. Higher Mortality

Heat waves combined with hot drinking water increase mortality — especially in closed farms.

5. Poor Egg Production in Layers

Temperature affects shell quality, yolk color, and feed intake.


3. Engineering Challenges in UAE Climate

UAE farms face unique conditions:

Outdoor tank temperature can exceed 50°C

High ambient temperature

Long piping networks (60–120 meters)

Poor insulation in many older farms

Continuous demand from birds


This means the cooling load must be calculated with higher accuracy.


4. Cooling Load Calculation (The DURUB Method)

When cooling a 500-gallon (≈ 1,890 L) tank, DURUB engineers consider:

✔ Initial water temperature (up to 45°C)

✔ Target temperature (18–22°C ideal for birds)

✔ Distance between chiller and tank (2–120 meters)

✔ Pipe heat gain along the farm

✔ Pump circulation speed

✔ Simultaneous water usage

✔ Outdoor heat + tank exposure


5. Why a Safety Factor Is Necessary

  • Cooling systems in farms face unpredictable loads:
  • sudden peak drinking by birds
  • sudden temperature spikes
  • heat transfer through long pipe runs
  • additional water entering tank during daytime


So

DURUB applies a 30% Design Safety Factor (DSF) for accurate cooling performance in UAE summer.

This ensures continuous stable water temperature even at peak demand.


6. Recommended Cooling System Setup

1. Chiller Unit

Capacity depends on tank volume + pipe distance:

2–3 Ton Chiller → small farms

3–5 Ton Chiller → medium farms

5+ Ton Chiller → large farms or long pipe runs


2. Circulation Pump

Must match the chiller flow rate.

Incorrect pump size = ineffective cooling.

3. Insulated Tank (Optional but recommended)

Even simple insulation reduces heat gain by 40–60%.

4. Return Loop Piping

Flow must be continuous to avoid temperature layering.

5. Control Panel

Includes:

digital thermostat

safety cut-off

circulation control

alarm indication (optional)


6. Flow Balance & Pressure Management

Correct balancing ensures equal cooling across all drinker lines.


7. Common Mistakes in Farm Cooling Systems

Many farms fail because of:

using domestic chillers (not for farms)

undersized circulation pump

long pipe run without compensation

no insulation

wrong thermostat placement

cheap piping that absorbs heat

tank placed directly under sunlight


DURUB’s engineering eliminates these issues completely.


8. DURUB Cooling System Packages

Standard Cooling Package

* 2–3 Ton industrial chiller
* Circulation pump
* Basic temperature controller
* Suitable for small farms

Advanced Cooling Package

* 4–5 Ton industrial chiller
* Engineered circulation loop
* Digital control panel
* Optional tank insulation
* Suitable for medium–large farms

Premium High-Load Package

* High-capacity chiller
* Automatic flow control
* Full monitoring panel
* Designed for long-distance piping (120m)
* Ideal for commercial farms with high density


9. Operating Cost & Efficiency

Correctly designed cooling systems reduce:

bird mortality

feed waste

medical treatment costs

overall energy consumption


ROI (return on investment) is achieved in a few months due to better weight gain and lower losses.


10. Conclusion

Water tank cooling is a crucial part of maintaining healthy and productive poultry operations in the UAE’s extreme climate.
A properly engineered system ensures stable water temperatures, healthier birds, and higher farm profit.

DURUB delivers professional cooling solutions engineered specifically for UAE farms.

📞 +971 54 238 8884
🌐 durubco.com

Leave a Reply

Your email address will not be published. Required fields are marked *